This page is for anyone reproducing a result from another simulator or from the model in a paper, and for coding agents doing the same. It lists the conventions Skarstrom uses where codes commonly differ, with the formula the engine evaluates and the parameter you set. Python names (sim.adsorbents[0].solid_density) and registry paths (adsorbent[1].solid_density) are given side by side; see Python and the Command Line for how to set them.

All values are SI unless a unit is given (2 * u.min, "2 [min]").

Densities and voidages

Bulk density and solid_density

solid_density is the particle (pellet) density \(\rho_s\): the mass of an adsorbent particle divided by its volume, pores included. It is not the skeletal (crystal) density and not the bed's bulk density. The bulk density, the mass of adsorbent per m³ of bed, is

\[ \rho_b = (1 - \epsilon_b)\thinspace \rho_s \]

with \(\epsilon_b\) the layer's inter-particle voidage, layer[ID].bed_void_fraction. \(\rho_b\) multiplies every loading rate in the mass and energy balances, so the loading \(q\) (mol kg⁻¹) is per kg of particle, binder included.

Converting from what a paper gives:

The source gives Set solid_density to
particle / pellet / apparent density \(\rho_p\) \(\rho_p\)
bulk (packing) density \(\rho_b\) \(\rho_b / (1 - \epsilon_b)\)
skeletal / crystal / true density \(\rho_{cr}\) \((1 - \epsilon_p)\thinspace \rho_{cr}\)

Example: a column packed with 13X at a bulk density of 660 kg m⁻³ and \(\epsilon_b = 0.41\):

sim.layers[0].bed_void_fraction = 0.41
sim.adsorbents["13X"].solid_density = 660 / (1 - 0.41)    # 1118.6 kg/m3 of particle

A layer of several adsorbents (composition mass fractions \(w_k\)) uses the mixture particle density \(\rho_s = 1 / \sum_k (w_k / \rho_{s,k})\), and each adsorbent's own bulk density is \(\rho_{b,k} = (1-\epsilon_b)\thinspace \rho_s\thinspace w_k\).

The mass fractions of a layer must sum to 1 (within \(10^{-6}\)) and none may be negative; otherwise the deck checks refuse the deck (CheckLayerComposition in porous_media.h, which sim.check() and every run use). The fractions are never renormalised. A solid at mass fraction 0 is allowed but takes no part in the run, and the run-start warnings say so. A solid whose components all use the Inert isotherm is a valid member of a blend (an inert diluent or packing). A solid that is part of a blend (a layer that also holds another solid) cannot be removed from the deck until it has been taken out of that layer's composition. The blend edits of deck_edit.h (AddSolidToLayer, SetLayerMassFraction, RemoveSolidFromLayer) keep the fractions summing to 1 by rescaling the other solids in proportion.

Varying a fraction in a study. A mass fraction is a number, not an expression, and changing one solid's fraction on its own breaks the sum. So the deck checks refuse it, and the error says how to proceed: set all of the layer's fractions together at each point. For two solids that means \(x\) and \(1 - x\). In Python:

import skarstrom as sk

base = sk.Simulation("blend.json")          # one layer of "13X" and "Glass beads"
for x in (0.6, 0.7, 0.8, 0.9):
    sim = base.copy()
    sim.layers[0].set_composition({"13X": x, "Glass beads": 1 - x})
    result = sim.run()
    print(x, result.status, sim.kpis(cycle=-1))

From the command line, give both paths in the same run (the IDs are those of skarstrom params blend.json --search mass_fraction):

skarstrom run blend.json --set "layer[1].mass_fraction[1]=0.7" --set "layer[1].mass_fraction[2]=0.3" --json -q

A sensitivity study (skarstrom.sensitivity) varies each path on its own, so it cannot vary a blend's fraction. Use a loop like the one above.

Total voidage

The gas held in the bed (the accumulation terms of the mass and energy balances) uses the total voidage

\[ \epsilon_t = \epsilon_b + (1 - \epsilon_b)\thinspace \epsilon_p \]

with \(\epsilon_p\) the adsorbent's particle_void_fraction (adsorbent[ID].particle_void_fraction; for a mixed layer the solid-volume-weighted average). The gas in the macropores is assumed to have the composition of the gas between the particles: there is no separate pore-gas balance.

Three voidages enter in different places:

Parameter Symbol Used in
layer[ID].bed_void_fraction \(\epsilon_b\) \(\rho_b\), \(\epsilon_t\), the axial dispersion term (\(\epsilon_b D_{ax}\)), the momentum balance
adsorbent[ID].particle_void_fraction \(\epsilon_p\) \(\epsilon_t\) only
adsorbent[ID].kinetics[C].macropore_void_fraction \(\epsilon_p\) in the rate the macropore rate coefficients only (see Kinetic Models)

The last two are separate parameters; changing one does not change the other. Set both when the source model has one particle porosity used in both places.

When the other code has no particle porosity (its gas accumulation term uses \(\epsilon_b\) alone, or it writes \(\epsilon\) for both), set particle_void_fraction to zero, so that \(\epsilon_t = \epsilon_b\), and keep the macropore voidage of the rate model:

ads = sim.adsorbents["13X"]
ads.particle_void_fraction = 0.0                   # eps_t = eps_b
ads.kinetics["CO2"].macropore_void_fraction = 0.35  # still used by the macropore k

Check the other model's density at the same time: if its solid term is \((1-\epsilon)\rho_s\) with \(\epsilon\) its only voidage, its \(\rho_s\) is a particle density in the sense above.

Where in the code: MixedAdsorbentLayer::GetBulkDensity, GetTotalVoidFraction, GetEffectiveSolidDensity and GetEffectiveParticleVoidFraction (core/include/adsim/objects/porous_media.h, core/src/objects/porous_media.cpp).

Heat of adsorption sign

adsorbent[ID].heat_of_adsorption[C] (Python sim.adsorbents[0].heat_of_adsorption["CO2"]) is entered as a positive number for exothermic adsorption: the heat released per mole adsorbed, in J mol⁻¹. Its registry bounds are 0 to 10⁶. The energy balance adds the source

\[ S = \sum_k \sum_i \Delta H^{\mathrm{eff}}_{k,i}\thinspace \rho_{b,k}\thinspace \frac{\partial q_{k,i}}{\partial t} \quad [\mathrm{W\,m^{-3}}] \]

on the heating side of the balance, so a loading bed (\(\partial q/\partial t > 0\)) warms and a desorbing bed cools. How \(\Delta H^{\mathrm{eff}}\) follows from the stored value is set by fluid.heat_of_adsorption_convention:

fluid.heat_of_adsorption_convention The stored value is \(\Delta H^{\mathrm{eff}}\)
"isosteric" (default) the isosteric heat \(q_{st} = -\Delta H_{ads}\) stored value
"internal_energy" the internal-energy form of Haghpanah et al. (2013) stored value \(- C_{pa,i}\thinspace T\)
"isosteric_rt" \(-\Delta U_{ads}\) stored value \(+ R\thinspace T\)

\(T\) is the adsorbed-phase temperature (the bed temperature in LTE, the solid temperature in LTNE) and \(C_{pa,i}\) the adsorbed-phase molar heat capacity (fluid.adsorbed_heat_capacity_mode and fluid.adsorbed_heat_capacity[C]; in the default constant mode it is 0 unless set, and then internal_energy gives the same result as isosteric).

Worked sign example. A paper reports the adsorption enthalpy of CO₂ on 13X as \(\Delta H = -37\) kJ mol⁻¹ (negative: exothermic). Enter its magnitude:

sim.adsorbents["13X"].heat_of_adsorption["CO2"] = 37e3     # J/mol, positive
sim.fluid.heat_of_adsorption_convention = "isosteric"       # the default

If the bed takes up CO₂ at \(\partial q/\partial t = 10^{-3}\) mol kg⁻¹ s⁻¹ with \(\rho_b = 660\) kg m⁻³, the source is \(37\,000 \times 660 \times 10^{-3} = 24.4\) kW m⁻³ of heating. Had the paper instead reported \(\Delta U = -35\) kJ mol⁻¹ in an energy balance written with \(-(\Delta U - RT)\), enter 35e3 with "isosteric_rt": at 300 K, \(\Delta H^{\mathrm{eff}} = 35\,000 + 8.314 \times 300 = 37\,494\) J mol⁻¹. Entering a negative number would make adsorption cool the bed.

The energy balance always uses this stored value; it never derives a heat of adsorption from the temperature dependence of the isotherm. If the isotherm has its own energy parameter (for example the exponent of a temperature-dependent affinity), set it separately and consistently, in the sign convention of that isotherm's formula on the Isotherms page.

Where in the code: AdsorptionHeat and the energy residuals in core/src/equations/adsorbent_equations.cpp; HeatOfAdsorptionConvention in core/include/adsim/objects/fluid.h.

Composition used by the rate models

There is one gas phase per cell. Every rate model evaluates the equilibrium loading \(q_i^*\) from the isotherm at the cell's bulk gas mole fractions \(y\) and pressure \(P\) and the adsorbed-phase (solid) temperature; there is no separate macropore or surface concentration.

The capacity-factor macropore rate (set_rate_model(C, "ldf", "macropore_capacity", ...))

\[ k_i = \frac{15\thinspace \epsilon_p D_{m,i}}{\tau\thinspace r_p^2}\thinspace \frac{c_i}{\rho_s\thinspace q_i^*}, \qquad c_i = \frac{y_i P}{R T} \]

uses:

  • \(c_i\): the cell's bulk gas concentration of component \(i\), from that cell's \(y_i\), \(P\) and gas temperature \(T\), floored at kinetics[C].concentration_floor (default 10⁻³ mol m⁻³);
  • \(q_i^*\): the isotherm at that same cell, with \(y_i\) replaced by its floored value and every other component at its actual value (under the IAST mixing rule, the IAST mixture loading at that state);
  • \(\rho_s\): the adsorbent's solid_density (the particle density above);
  • \(\epsilon_p\): kinetics[C].macropore_void_fraction (not particle_void_fraction);
  • the ratio \(c_i/(\rho_s q_i^*)\) capped at 1.

So the rate is not evaluated at the feed composition or at a pore-gas composition, but at the local bulk gas of each cell at each instant.

Where in the code: MassTransferCoefficientMacroporeCapacity::UpdateMassTransferCoefficient (core/src/equations/mass_transfer_model.cpp).

Boundary-value profiles

Each flow, inlet temperature and pressure at a step end can follow a profile in time. \(t\) is the time since the start of the step, \(v_0\) the start value, \(v_1\) the end value, \(t_r\) the ramp time.

Kind (sk.<kind>) Formula After \(t_r\)
constant(v) \(v(t) = v\) —
linear(end, start=, time=) \(v_0 + (v_1 - v_0)\thinspace \min(t, t_r)/t_r\) held at \(v_1\)
exponential(end, start=, time=, factor=) \(v_1 + (v_0 - v_1)\thinspace F^{-t/t_r} = v_1 + (v_0 - v_1)\thinspace e^{-\ln(F)\thinspace t/t_r}\) keeps approaching \(v_1\)
log_linear(end, start=, time=) \(v_0\thinspace (v_1/v_0)^{\min(t, t_r)/t_r}\) (linear if \(v_0 \le 0\) or \(v_1 \le 0\)) held at \(v_1\)
double_exponential(end, rate_1, rate_2, weight, start=) \(v_1 + (v_0 - v_1)\left[w\thinspace e^{-r_1 t} + (1-w)\thinspace e^{-r_2 t}\right]\) keeps approaching \(v_1\)

\(F\) is the exponential factor (..._exponential_factor, default 100, must exceed 1): after \(t_r\) the change left is \(1/F\) of the initial one, so \(F = 100\) has covered 99 %. A ramp time of zero is an immediate step to \(v_1\). To match a model written as \(v_1 + (v_0 - v_1)e^{-t/\tau}\), keep any \(t_r\) and set \(F = e^{t_r/\tau}\); for example \(\tau = 5\) s with \(t_r = 20\) s gives \(F = e^4 = 54.6\).

Flows and inlet temperatures use the start value and ramp time you give (endpoint[ID].velocity_linear_start, ..._linear_end, ..._linear_time, and so on).

Pressures (a pressure boundary, or a valve's set pressure) differ in two ways:

  • the start value is the bed pressure at the bed-end face at the start of the step (the mean of the end cell and the ghost cell); there is no start parameter;
  • the ramp time is the step time unless endpoint[ID].pressure_<kind>_use_step_time is false, in which case it is endpoint[ID].pressure_<kind>_time, which must not exceed the step time. For the exponential this means \(F\) is reached at the end of the step by default.
step.top.set_pressure("outlet", sk.exponential(1e4, factor=50))            # 1e4 Pa approached, 98 % by the step end
step.top.set_pressure("outlet", sk.exponential(1e4, time=10, factor=100))  # 99 % after 10 s
sim["endpoint[3].pressure_exponential_factor"] = 50                         # the same through the registry

Where in the code: core/src/boundary_conditions/boundary_value.cpp (the formulas); PressureBoundaryCondition::Initialise (core/src/boundary_conditions/boundary_conditions.cpp) and core/src/boundary_conditions/boundary_stream.cpp (the pressure start value and ramp time). Boundary Conditions describes each profile in more detail.

Velocity, volumetric and molar feeds

A flow boundary's velocity is the superficial velocity (flow over the empty column cross-section). Velocity and volumetric flow are converted to a molar flow with the ideal-gas concentration at the bed-end face, at its current pressure and temperature:

\[ \dot n = u\thinspace A\thinspace \frac{P_f}{R\thinspace T_f}, \qquad P_f = \tfrac12 (P_{\text{ghost}} + P_{\text{end cell}}), \quad T_f = \tfrac12 (T_{\text{ghost}} + T_{\text{end cell}}) \]

So a velocity or volumetric feed is an actual volumetric flow at the bed inlet, not at standard conditions, and its molar flow changes as the bed pressure changes during the step. A mass flow is divided by the face molar mass. If the other model specifies a molar flow, or a volumetric flow at standard conditions, use sk.molar_flow (convert a standard flow to mol s⁻¹ first) rather than sk.velocity.

Where in the code: core/src/boundary_conditions/flow_boundary_value.cpp.

Where profile values sit

The bed is cut into finite volumes; each layer has layer[ID].cells equal cells. \(z\) is measured from the bottom of the column (\(z = 0\)) to the top (\(z = L\)).

  • Cell variables (pressure, temperature, mole fraction, loading) are cell averages, located at the cell centres: sim.profile(...).z, the same as sim.positions. The first centre is half a cell above the bottom, not at \(z = 0\).
  • Face variables (velocity, volumetric and molar flow, approach to fluidisation) are at the cell faces, from 0 to \(L\) (sim.face_positions).
  • The bed ends: use sim.series(var, location="bottom") or location="top". For pressure, temperature and mole fraction this is the step endpoint's logged value: at an inlet the value the boundary imposes (feed composition and temperature, set pressure), at an outlet the bed-end face value. A closed end, and every other variable, gives the face value.
  • Any position: sim.series(var, z=0.15) interpolates linearly between cell centres, and between the end cell and the bed-end value above in the last half-cell at each end.
p = sim.profile("mole_fraction", "CarbonDioxide", step=0)
p.z[0]         # 0.5 * L / cells for a single layer: not the inlet
y_out = sim.series("mole_fraction", "CarbonDioxide", location="top")   # outlet value

When comparing with a code that stores nodes at the bed ends (a finite-difference or collocation grid with a node at \(z = 0\) and \(z = L\)), compare its end nodes with location=, and its interior nodes with series(z=...) at the same \(z\), not with profile(...).values[:, 0].

Where in the code: Simulation::Positions, FacePositions and Series (core/include/adsim/simulation.h); core/src/solver/bed_series.cpp.

Checklist: settings that most often differ

Go through these before concluding that two models disagree.

Setting Skarstrom default Parameter
Advection scheme for the species balance WENO (third order) settings.advection_scheme: "upwind", "weno", "van_leer"
Number of cells per layer layer[ID].cells
Gas heat capacity CoolProp, per component, evaluated once at the initial-condition pressure and temperature and held for the run fluid.gas_heat_capacity_mode ("coolprop", "constant"), fluid.gas_heat_capacity[C] in J mol⁻¹ K⁻¹
Gas viscosity mole-fraction average of pure-component \(\mu_i(T)\) polynomials fluid.viscosity_mode ("polynomial", "constant"), fluid.viscosity in Pa s
Heat-of-adsorption form isosteric fluid.heat_of_adsorption_convention (see above)
Adsorbed-phase heat capacity constant, 0 J mol⁻¹ K⁻¹ fluid.adsorbed_heat_capacity_mode, fluid.adsorbed_heat_capacity[C]
Feed specification as built sk.velocity (actual flow at the bed face) vs sk.molar_flow (see above)
Particle porosity in the gas hold-up \(\epsilon_t = \epsilon_b + (1-\epsilon_b)\epsilon_p\) adsorbent[ID].particle_void_fraction (0 for \(\epsilon_t = \epsilon_b\))
Density basis particle density adsorbent[ID].solid_density
Energy balance non-isothermal, LTE energy_balance.energy_balance_mode, bed.thermal_equilibrium_mode ("lte", "ltne")
Valve bed-side pressure the bed-end face settings.valve_bed_pressure ("face", "end_cell")

Notes on the rows:

  • Advection scheme and cells. Upwind smears fronts and needs several hundred cells for a recovery within 0.1 percentage point; WENO reaches the same on tens of cells (Numerics). A reference code with first-order upwinding on 10-30 cells differs from Skarstrom's WENO default by its numerical dispersion: set "upwind" and the same cell count to reproduce it, or refine both. The scheme sets the convective face temperature of the energy balance as well as the face mole fractions.
  • Gas heat capacity. The mixture value is mixed on a molar basis, \(C_{p,g} = \sum_i y_i M_i C_{p,i} / \sum_i y_i M_i\) (J kg⁻¹ K⁻¹), in every cell. Many papers use a constant molar value (e.g. 30.7 J mol⁻¹ K⁻¹ for every component): set "constant" and that value for each component.
  • Viscosity. A constant fluid.viscosity is used in every cell at every temperature and composition.
  • Dispersion. The dispersive flux is \(\epsilon_b D_{ax}\thinspace C\thinspace \partial y/\partial z\); a model that multiplies \(D_{ax}\) by \(\epsilon_t\), or not at all, needs its \(D_{ax}\) rescaled. No dispersive flux crosses the bed-end faces (Danckwerts inlet; Mass Balance).
sim.settings.advection_scheme = "upwind"
sim.layers[0].cells = 30
sim.fluid.gas_heat_capacity_mode = "constant"
for c in ("CO2", "N2"):
    sim.fluid.gas_heat_capacity[c] = 30.7          # J/(mol K)
sim.fluid.viscosity_mode = "constant"
sim.fluid.viscosity = 1.72e-5                      # Pa s

Finally, re-run on twice the cells: a disagreement that changes with the grid is a numerical one.