Solver Settings

Once the fluid, adsorbents, column and cycle are defined, the deck can be run. Skarstrom integrates the coupled governing equations in time as a system of differential-algebraic equations (DAEs) using a variable-order, variable-step implicit method (SUNDIALS IDA), taking the bed through every step of every cycle.

## Running, stopping and monitoring

  • Run. sim.run() (Python), skarstrom run deck.json (CLI) or adsim::Simulation::Run (C++) validates the deck, evaluates every expression and integrates all cycles. If validation fails the run returns status failed with the reason in message; nothing is integrated.
  • Progress and cancel. sim.run(progress=f) calls f(info) after every step with the cycle, step and completed fraction; return False to cancel. Ctrl-C cancels a Python run cleanly.
  • Status. One of completed, reached_css (reached CSS before the cycle limit), failed or cancelled.
  • Solver log. sim.run(log_level="medium", on_message=f) passes the solver's messages to f(level, text); skarstrom run --log medium prints them. Low reports essential milestones, medium adds per-cycle and per-step progress and CSS checks, high adds diagnostics. The run result carries the runtime and solver statistics (steps taken, residual evaluations, non-linear iterations, error-test and convergence failures).

Solver settings

The solver parameters are stored in the deck and are parameters of the registry (settings.*; skarstrom params deck.json --all lists them with their values). The defaults are robust for typical PSA/TSA problems; adjust them only when a run struggles to converge or you need tighter accuracy. The Numerics page explains what each one does inside the integrator.

Setting Parameter Default Meaning
Maximum Time Step settings.max_step 0 (no limit) Largest step the integrator may take; 0 leaves the step size to IDA's error control. Lowering it can stabilise stiff, fast-transient steps. Results are logged from IDA's interpolant, so the logged trajectory does not depend on it. Decks saved with the old default of 2 s load with no limit.
Minimum Time Step settings.min_step 1×10⁻¹⁵ s Smallest permitted step.
Initial Step Size settings.init_step 1×10⁻¹⁰ s First step attempted.
Relative Tolerance settings.reltol 1×10⁻⁶ Relative accuracy target per variable. Tighten for more accuracy, loosen to speed up a hard run.
Maximum BDF Order settings.max_order 5 Highest order of the backward-differentiation formula (1–5).
Maximum Nonlinear Iterations Per Step settings.max_nonlin_iters 15 Newton iterations allowed per step before the step is retried smaller.
Nonlinear Convergence Coefficient settings.nonlin_conv_coef 0.1 Safety factor on the Newton convergence test (0–1).
Maximum Convergence Failures settings.max_conv_fails 200 Non-linear-solver failures tolerated before giving up.
Maximum Error Test Failures settings.max_err_test_fails 40 Local error-test failures tolerated before giving up.
Maximum Number of Steps settings.max_num_steps 100000 Cap on total integrator steps.
Advection Scheme settings.advection_scheme weno Face reconstruction of the mole fractions and of the energy balance's convective face temperature: weno (third order), van_leer (limited second order) or upwind (first order, the default up to engine 0.4). WENO reaches a grid-converged result on 4-10 times fewer cells than upwind; see Numerics.
Maximum Number of Cycles to Log settings.max_cycles_to_keep 10 How many recent cycles of full profile data are retained for plotting. Every solver step of each kept cycle is stored, so this sets most of a run's memory (on a fine grid, hundreds of MB per cycle). KPIs are kept for every cycle whatever this is. With a CSS method on, at least the cycles the CSS check reads are kept (4 with the default three consecutive cycles).

Absolute tolerances are set internally on a per-variable basis (10⁻⁸ for concentrations, mole fractions and loadings, 10⁻⁶ for pressure and velocity, 10⁻⁴ K for temperatures), so only the single relative tolerance is a setting. See Numerics.

Warnings

A run reports advisory warnings in the solver log; none of them stops it. Each can be switched off in the deck (in the web workspace: the Solver window's Warnings tab, or Turn off on a warning in the Solver Log). A switched-off warning is not logged and not listed by sim.operating_limits(), whose per-step extremes stay complete.

Warning Parameter When
Pressure step change settings.warn_pressure_step_change Start of a run: a step's constant pressure boundary is more than 25 % from the pressure the bed starts the step at; a ramp avoids the instantaneous change.
Wall thickness settings.warn_wall_thickness Start of a run: the wall is thinner than its pressure design requires.
Design pressure settings.warn_design_pressure End of a run: the last cycle's pressure passes the wall's design pressure.
Vacuum settings.warn_vacuum End of a run: the last cycle goes below atmospheric and the wall is not in vacuum service.
Design temperature settings.warn_design_temperature End of a run: the wall temperature passes the design temperature.
Fluidisation settings.warn_fluidisation End of a run: the approach to fluidisation passes 1. Switch it off for a bed that is held down.

All are on by default. The end-of-run checks are described on Wall Design and Operating Limits.

Troubleshooting convergence

  • The run fails early with a message about consistent initial conditions. The solver could not reconcile the initial conditions with the first step's boundary conditions. Make the initial pressure, temperature and composition physically consistent with what the first step imposes.
  • The run stalls or reports many convergence/error-test failures. Reduce settings.max_step and/or loosen settings.reltol slightly; check for very stiff inputs (e.g. an extremely large mass-transfer coefficient or a near-instant pressure ramp). Increasing the layer's number of cells gradually rather than in one large jump also helps.
  • Results look under-resolved. Increase the layer's number of cells and re-run; confirm the results stop changing. With the default WENO scheme about 80 cells resolve a 0.3 m VSA column; upwind needs several times more (Numerics).

Once a run completes, retain enough cycles (settings.max_cycles_to_keep) to inspect the approach to cyclic steady state and to compute performance metrics.